Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T06CM01870
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/18/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
05/16/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) USED APPROVED BOXES FOR CEILING FANS YOU HAVE LIGHT FIXTURE BOXES 2) NON-METALLIC CONDUIT TO BE UNDER CONCRETE, OR 18" BELOW GRADE 3) MAKE SURE MOTION DETECTOR, FIXTURES WON'T BE DAMAGED BY ROOF H20 RUN OFF 4) INSTALL GROUND SCREW AND BOND JUMPER TO SCREW ON ALL METAL BOXES |