Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01870

Parcel: 136100610

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T06CM01870

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2006 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/10/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LAYOUT OK
2) PLAN CALLS FOR 1 #4 VERTICAL IN EACH CORNER OF POST FOOTINGS. TOTAL OF 4 EACH COLUMN
3) #4 REBAR MUST OVER LAP AT LEAST 20" AT CONNECTION POINTS
4) AT CORNERS, BEND AT 40" PIECE OR LONGER TO GET MINIMUM 20" OVER LAP EACH SIDE
5) NEED MINIMUM 3" CLEAR REBAR TO DIRT IN POST FOOTINGS