Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM01870
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/12/2006 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
04/10/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LAYOUT OK 2) PLAN CALLS FOR 1 #4 VERTICAL IN EACH CORNER OF POST FOOTINGS. TOTAL OF 4 EACH COLUMN 3) #4 REBAR MUST OVER LAP AT LEAST 20" AT CONNECTION POINTS 4) AT CORNERS, BEND AT 40" PIECE OR LONGER TO GET MINIMUM 20" OVER LAP EACH SIDE 5) NEED MINIMUM 3" CLEAR REBAR TO DIRT IN POST FOOTINGS |