Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T06CM01844
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/19/2006 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* OK FOR FINAL |
|
07/18/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* MARK UNIT DATA PLATE W/PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY. CONDENSATE TRAPS NOT BUILT CORRECTLY. DRAIN RUNS UPHILL. BLOCK & CLAMP EVERY 4'. PAINT W/LATEX PAINT. PROVIDE ROOF JACKS. DRAIN PIPES LEAKING. ONE DETECTOR NON-OP |
|
07/17/2006 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* | |
07/10/2006 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* - FINISH WORK ON ROOF - RELOCATE DUCT SMOKE DETECTOR AC-1 - PROVIDE VISIBLE & AUDIBLE ALARMS IN A SUPERVISED LOCATION - OK FOR CEILING TILES. LEAVE OUT UNDER EACH DUCT SMOKE DETECTOR. NEED TO TEST DETECTORS. |