Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01828
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING SHEAR NAILING FRONT S/WEST 2) LTP 4'S AT SHEAR TO BOTTOM CHORDS 3) MISSING WIND BRACE 2ND FLOOR REAR 4) TWO NAILS IN EACH WIND BRACE TOP/BOTTOM PLATES 5) 1ST AND 2ND FLOOR STRAPS 4'-0" ON CENTER 6) REAR POST COLUMNS NOT SECURED 7) FRONT SHED ROOF NAIL EDGE AND BLOCK TIE TO BLDG 8) REAR PORCH DECK MISSING RIPPER 9) NO ACCESS TO ROOF |