Permit: T06CM01817

Parcel: 11518041K


Addresses:

802 W SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/06/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
CORRECTIONS MADE OK
PLUMBING FINAL OK
OK FOR C OF O S.T.O.I
12/05/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
MINIMUM ONE INCH AIRGAP IS NOT NEGOTIABLE
12/02/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. COMPOSITE BOARD IS NOT APPROVED MATERAL FOR PIPE SUPPORT.
2. MAY NOT CONNECT SOAP DISPENSER AT JANITOR FAUCET.
11/28/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. INDIRECT WASTE PIPING BETWEEN FIVE AND FIFTEEN FEET IN DEVELOPED LENGTH SHALL BE DIRECTLY TRAPPED AND BE INSTALLED IN A WORKMANSHIP LIKE MANNER USING APPROVED MATERIALS.
11/23/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) REMOVE TEST PLUGS AND INSTALL COUNTER ? TAPPED CLEANOUT PLUGS WITH 5/16" MACHINE SCREW
2) ALL INDIRECT WASTE PIPING TO BE APPROVED MATERIAL AND INSTALLED PER 2003 UPC
3) INDIRECT WASTE PIPING BETWEEN 5-15 FEET TO BE DIRECTLY TRAPPED
4) REQUIRE AIR GAP AT I W PIPING
5) I W PIPING MAY NOT BE COMBINED