Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01812
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2006 | FRAMING | Approved | IVRS - Inspection :* | |
07/28/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM BEARING HEADERS 2) UPSTAIRS SHEARWALL (4) STAIR WELL OSB DOES NOT REACH TOP 3) U-VALUE FOR WINDOW PARTIAL EXCEPT BED 2 WINDOW 4) REINFORCE WINDOWS 5) NO GAS LINES INSTALLED AT THIS TIME 6) MISSING HOLDOWN STAIRWELL (4) WALL 7) FIRE STOP TUB SHOE TO SECOND FLOOR 8) FIRE BLOCK MISSING W/H PLENIUM 9) NO WATER TEST DWV SYSTEM 10) FIRE STOP WATER HEATER FLUE IN CHASE TOP PLATE |