Date Description Inspector Results Comments
08/10/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/08/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 2ND FLOOR SHEAR SEE SHEAR PLAN 2ND FLOOR SHEAR RUNS TO OUTSIDE OF WALL. REMOVE TO NEXT STUD AND INSTALL OSB MISSING WIND BRACE
2) WRONG NAILS HANGERS NO 8D
08/07/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS TO ALL ROOFS
2) COMPLETE WEST END X BRACING
3) CLIP OR LAG LEDGER ON PATIO