Permit: T06CM01802


Addresses:

8331 S OTIS DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01802

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/18/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 2-10D'S NAILS IN ALL WIND BRACES AT B/TOP PLATE
2) (4) SHEAR ACROSS TOP OF GARAGE FRONT WALL AND 36" LONG DRAG STRUT AT EACH SIDE OF GARAGE OPENING
3) MISSED 4'-0" SHEAR SOUTH SIDE
4) MISSED 2 WIND BRACES NORTH WALLS
5) LOOSE BOTTOM PLATE FRONT DOOR
6) 5/D3 SPACING OF 16D AT SHEAR TRANSFER 4" ON CENTER
7) 4 BRACE TRUSSES AT EACH END AND 25' ON CENTER