Permit: T06CM01769

Parcel: 111071400

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/16/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/15/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN 4' BETWEEN HANGERS FOR ABS, ALL VERTICAL PIPE TO BE SUPPORTED.
2. ALL PIPING WITHIN 1 1/4" OF STUD FACE TO BE PROTECTED
3. PLUMBERS TAPE NOT AN APPROVED STRAP
4. ALL ACTIVE HOSE BIBBS TO HAVE AVB'S
5. INSPECTION STOPPED

CONTINUED "NOT READY" WILL
RESULT IN A REINSPECTION FEE