Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM01754
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* ADDRESS NOT POSTED |
|
04/25/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PIPE WRAP OK DRAINAGE CONNECTION NOT COMPLETE OR CORRECT SEE NOTES. INSTALL DRAINAGE PER 2003 UPC |
|
04/20/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE LONG RADIUS DRAINAGE FITTING FOR LAV DRAIN (WEST LAV AREA). 2. EAST LAV AREA SHALL HAVE NO MORE THAN 1 90 DEG. CHANGE OF DIRECTION ON DRAIN ARM. 135 DEG. MAX 3. PROVIDE CORRECT TRANSITION COUPLINGS AT VENT OVRHEAD IN EAST RESTROOM 4. PROVIDE FOAM WRAP AT PIPE PENETRATION THRU CONCRETE. |