Permit: T06CM01754

Parcel: 11460019C

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM01754

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/27/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
ADDRESS NOT POSTED
04/25/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PIPE WRAP OK
DRAINAGE CONNECTION NOT COMPLETE OR CORRECT
SEE NOTES. INSTALL DRAINAGE PER 2003 UPC
04/20/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE LONG RADIUS DRAINAGE FITTING FOR LAV DRAIN (WEST LAV AREA).
2. EAST LAV AREA SHALL HAVE NO MORE THAN 1 90 DEG. CHANGE OF DIRECTION ON DRAIN ARM. 135 DEG. MAX
3. PROVIDE CORRECT TRANSITION COUPLINGS AT VENT OVRHEAD IN EAST RESTROOM
4. PROVIDE FOAM WRAP AT PIPE PENETRATION THRU CONCRETE.