Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01750
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) FOR FRAME INSPECTION, NAIL OFF RETRO H/D |
|
| 07/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS/PERMIT VISIBLE |
|
| 07/07/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED RETRO H/D NE CORNER 2. CHECK AND RE-NAIL ENTIRE ROOF 3. 6 PLACES MARKED IN BLACK ON SOUTHSIDE 4. PA STRAPS TO BE NAILED OFF WITH 16D SINKERS PER SIMPSON. 3 1/4" X .148 YOU USED 10D (3X.131) 5. SHIM 3 PT BEARING TRUSSES. 6. TRIM PLATE UNDER A11 2 PLY WHERE NON-BEARING. |