Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01750


Addresses:

9923 E KARST PL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01750

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/13/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) FOR FRAME INSPECTION, NAIL OFF RETRO H/D
07/12/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/PERMIT VISIBLE
07/07/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NEED RETRO H/D NE CORNER
2. CHECK AND RE-NAIL ENTIRE ROOF
3. 6 PLACES MARKED IN BLACK ON SOUTHSIDE
4. PA STRAPS TO BE NAILED OFF WITH 16D SINKERS PER SIMPSON. 3 1/4" X .148 YOU USED 10D (3X.131)
5. SHIM 3 PT BEARING TRUSSES.
6. TRIM PLATE UNDER A11 2 PLY WHERE NON-BEARING.