Permit: T06CM01745


Addresses:

9952 E CALDERA PL


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T06CM01745

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/01/2006 BUILDING - FINAL Approved IVRS - Inspection :*
10/30/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADD BLOCKING TO STRENGTHEN FURNACE PLATFORM OR ADDITIONAL LAYER OF OSB
2) OPEN NEUTRAL BEHIND DOOR N.W. BEDROOM
3) T/P LINE TO TERMINATE BETWEEN 6" + 12" OF FINAL GRADE