Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01745
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/24/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 07/19/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA STRAP OVER BORE AT GAS MAIN RISER 2) PROTECT WIRES FROM METAL TRUSS GUSSETS AND SECURE HANGING WIRES 3) ADD RED HEAD AT CUT PLATE AT S.W. CORNER IN MASTER BED 4) SECURE 4 GANG BOX IN MASTER BED 5) SHIM HEADER/TRIMMER CONNECTIONS WHERE NEEDED SEAL GARAGE LIGHT BOX, BOX ABOVE PANEL, BOX AND BOX HOLE OUTSIDE MASTER, FASCIA-FOAM INTERSECTIONS, A/C LINES, H20 MAIN 6) DWV OK 7) NEED H20 PRESSURE 8) LEAK AT WATER MAIN RISER |