Inspection History Details
Inspection Status: Partial Approval
Inspection History: BUILDING - FINAL
Permit Number - T06CM01722
Inspection Description - BUILDING - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/24/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) SWITCH FOR DISPOSAL RAMADA ? 2) DISHWASHER HOLDING WATER 3) DRAIN LOOP ? 4) DEN AND EXCERCISE ROOM FINALED 5) NEED BARBEQUE PAD |
|
07/20/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) DEN ADDITION ONLY: OK TO MOVE FURNITURE INTO DEN AREA 2) RECEPTACLE INOPERABLE AT DESK 3) EXPOSED LAMP NOT PERMITTED IN CLOSET 4) REMOVE TAPE FROM SINGLE WALL TO B-VENT 5) ADD DRIP LEG TO FURNACE 6) ADD OVERFLOW SHUT OFF SWITCH TO FURNACE OR SECONDARY CONDENSATE DRAIN 7) RAISE OPENING AT TEE ABOVE CONDENSATE DRAIN 8) REPAIR SHEETROCK FURNACE CEILING 9) CONDENSATE DRAIN CANNOT BE REDUCED IN SIZE |