Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01713
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2006 | FRAMING | Approved | IVRS - Inspection :* | |
12/05/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIE GARAGE SHEARWALL NOT BUILT TO FLOOR ABOVE 2) M/TOILET NOT PROPERLY VENTED 3) KITCHEN SUPPLY AIR DUCT RESTRICTED 4) DBL 2 X 6 HEADER MUST BEAR ON POST BY STAIR 5) STAIR RISE CHANGE MORE THAN 3/8" 6) OVER SPAN MIDDLE BEDROOM 7) PROVIDE DRYWALL NAILER MASTER BEDROOM 8) STUD SHOE 3 STUDS MASTER BATH LAV 9) BLOCK MASTER BATH FLOOR |
|
12/04/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER KEN |