Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM01710
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* OK TO POUR CONCRETE |
|
06/29/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* OK TO BACKFILL RECALL ROUGH SOIL INSPECTION AFTER INSTALLING FD'S AND TRAP PRIMER LINES PROVIDE FOAM PIPE WRAPS. |
|
06/27/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) YOU STILL HAVE A LEAK ON 4" COMBO USE A TORQUE WRENCH ON N H BANDS CHECK FOR LEAKS PRIOR TO INSPECTION |
|
06/26/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST IS DOWN BY 2' 2) THERE APPEARS TO BE A LEAK ON 4" COMBO AT P-2 3) ALL OTHER AREAS OK TO BACKFILL 4) CORRECT LEAK, EXPOSE NH BAND, RETEST 5) RECALL FOR INSPECTION |
|
06/23/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HAVE APPROVED PLANS ON SIGHT FOR INSPECTION. CORRECT SLOPE AT SOUTHERN MOST FD AND CORRECT BACKPITCH AT SOUTHEAST FDS FDS AND TRAP PRIMER LINES TO BE INSTALLED PRIOR TO CONCRETE. FOAM WRAP REQUIRED WHERE PASSING THRU CONCRETE. |