Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2008 | PLUMBING - FINAL | Approved | ||
| 11/13/2008 | PLUMBING - FINAL | Not ready for Inspection | 1. INSULATION AT MECHANICAL YARD COMPLETE 2. WATER LINE TO POOL REQUIRES A MINIMUM 12" OF COVER 3. HORIZONTAL CLEANOUT EXTENSION TO BE A WYE BRANCH FITTING 4. PAINT THE 90 DEG. ELL AT SUMP DRAIN 5. CONTRACTOR TO PAY REINSPECTION FEE |
|
| 11/12/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SUMP DRAIN NOT TERMINATED PROPERLY REMOVE COVER ON EWC 2. POOL WATER NOT INSPECTED - MIXING VALVES AT PUBLIC USE LAVATORIES - HAMMER ARRESTORS AT LAUNDRY - SUPPORT WASHER DRAINS - SUPPORT THE END OF THE GAS BRANCH - INADEQUATE NUMBER OF CLIPS ON SINK - CABINET TOP NOT SECURED - H/C WATER CLOSET HANDLE TO BE ON THE WIDE SIDE - WHERE IS C.O FOR JANITOR SINK - LAV FCT IN .134 - CLEANOUT REQUIRES CLEARANCE 138 - SUPPORT PIPING AT BACKFLOW PROTECTION - MISSING 90 deg's AT FLOOR SINK |
|
| 11/07/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 11/05/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1. YARD WATER OK TO COVER 2. ICE MAKER DRAINS TO BE SUPPORTED AIR GAP MUST BE MAINTAINED GRATE AND STRAINER ON FLOOR SINK 3. CAULK MOP SINK 4. REQUIRE BACKFLOW PROTECTION ON ICE MAKER |
|
| 11/03/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE NO APPROVED GAS PLAN YARDWATER LEAK, MISSING AVB |
|
| 10/20/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PLEASE CALL IN AND HAVE APPROVED, ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL 2. PROVIDE INSPECTION HISTORY FOR GAS PIPING IN THE WALLS. 3. HAVE PLUMBER COMPLETE HIS PUNCH LIST PRIOR TO CALLING FINAL. 4. CONTINUED "NOT READY" MAY RESULT IN A REINSPECTION FEE. |