Permit: T06CM01697

Parcel: 10704006C


Addresses:

1564 W GRANT RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/23/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. NO APPROVED GAS PLAN ON SITE. HAVE REVISED GAS PLAN APPROVED AND ALL AS-BUILT SIZES VERIFIED FOR ENGINEERING
2. WILL REQUIRE LETTER AS NOTED ON 7/16/08
3. WILL REQUIRE PLAN REVISION FOR AS-BUILT FROM 2/9/08
4. WILL REQUIRE STERILIZATION AND CLEAN BACTERIA REPORT FOR FINAL
07/22/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES 2ND FLOOR OK
07/16/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. ENGINEER HAS ACCEPTED INSULATION IN THE CORRIDORS ONLY. PROVIDE LETTER FROM OWNER ACCEPTING AS BUILT CONDITION - OWNER IS AWARE OF I.E.C.C REQUIREMENTS
2. CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR FLANGES TO BE SECURE
3. INSULATION FIRST AND SECOND FLOOR CORRIDORS ONLY
OK TO COVER SUBJECT TO OWNERS LETTER
07/15/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. CLOSET FLANGES TO BE SECURE. CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISH FLOOR. CLOSET FLANGES TO BE FULLY SOCKETED INTO PIPE OR INTO FITTING. PIPE SHALL BE FLUSH WITH THE TOP OF THE FLANGE. IT SHALL PRESENT A SMOOTH INTERIOR WATERWAY
2. PLAN SPECS AND I.E.C.C REQUIRE THAT ALL HOT AND ALL RECIRC. PIPING TO BE INSULATED
07/14/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
THIS INSPECTION FOR CLOSET FLANGES & ABOVE CEILING, CLOSET FLANGES TO BE SET ON FINISH FLOOR, TOP OF FLANGE 1/4" ABOVE FINISH FLOOR, FLANGE TO BE SECURED TO FLOOR WITH APP. FASTENERS, WITH FLUSH INTERIOR WATER WAY AND PIPE FLUSH TO TOP OF FLANGES. ABOVE CEILING PIPING TO BE SUPPORTED AT 32" INCREMENTS FOR PEX, PROPERLY INSULATED AND SEALED AND SUPPORTED.
07/11/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
COMPLETE INSULATION FOR ARMOR FLEX STANDARDS
07/03/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. CORRIDOR PIPING ON THE FIRST FLOOR INCOMPLETE
NO PROVISION MADE FOR INSULATION
2. CLOSET FLANGES 2ND FLOOR NOT SET
CONTINUED "NOT READY" WILL RESULT IN REINSPECTION FEE
03/12/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL ROOMS 2ND & 3RD FLOOR
NEED TO SEE CLOSET FLANGES
02/20/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/19/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. PROVIDE TEST ON ALL PIPING FOR 2ND FLOOR
2. PROVIDE APPROVED PLANS FOR WATER PIPING & WASHER AND VENTS
02/01/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. TUBS & SHOWERS FIRST FLOOR OK
2. OK TO COVER UNIT WALLS
3. WILL INSPECT CORRIDOR AT A LATER DATE
4. CLOSET FLANGES FIRST FLOOR OK
10/26/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO PRE-ROCK FIRST FLOOR
WILL REINSPECT FIRST FLOOR AFTER TUBS AND SHOWERS
CONTRACTOR WILL SUPPORT ALL STUB OUTS
09/26/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
COURTESY INSPECTION FOR INTERMEDIATE