Permit: T06CM01669


Addresses:

8349 S HUNNIC DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01669

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/06/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/03/2007 EXT METAL CLIPS/EXT SHEATHING Denied 1. SHEAR PANEL SOUTH REAR OF HOUSE NOT NAILED.
2. RSP4 CLIPS NEEDED AT SE CORNER BOTTOM PLATE
3. NEED PROTECTION PLATES AT ALL PLUMBING VENT - 2 PLCS
4. SHIM 3 PT BEARING TRUSS
5. SHEAR PANEL WALL NEEDS DBL STUDS AT NW CORNER OF HOUSE AND AT ENTRY.
6. 4' X 8' SHEAR PANEL SOUTH SIDE OF HOUSE MISSING A.B PER SHEAR WALL PLAN.
7. SHEAR WALL TRANSFER TO TRUSS NAILING NOT PER S/D2