Permit: T06CM01668


Addresses:

8341 S HUNNIC DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01668

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/09/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/06/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PORCH NOT TIED TO WALL
2) FLOOR NOT NAILED OFF
3) NAIL ALL HORIZONTAL JOINTS, SHEAR AND BELLY BAND
4) 1ST AND 2ND FLOOR STRAPS 4' ON CENTER
5) USE 16D'S IN GIRDER HANGERS
6) FRONT GABLE ROOFS NOT SECURED TO WALL
7) TIE ALL SHEARWALLS TO TOP PLATE PER SHEARWALL NUMBER
8) NAIL OFF THA FLOOR JOIST HANGER AT STAIR
9) MISSED 4' PANEL 2ND FLOOR REAR
10) 2 NAILS IN WIND BRACE, WIND BRACE MISSING NORTH WALL 1ST FLOOR