Inspection History Details
Permit: T06CM01668
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PORCH NOT TIED TO WALL 2) FLOOR NOT NAILED OFF 3) NAIL ALL HORIZONTAL JOINTS, SHEAR AND BELLY BAND 4) 1ST AND 2ND FLOOR STRAPS 4' ON CENTER 5) USE 16D'S IN GIRDER HANGERS 6) FRONT GABLE ROOFS NOT SECURED TO WALL 7) TIE ALL SHEARWALLS TO TOP PLATE PER SHEARWALL NUMBER 8) NAIL OFF THA FLOOR JOIST HANGER AT STAIR 9) MISSED 4' PANEL 2ND FLOOR REAR 10) 2 NAILS IN WIND BRACE, WIND BRACE MISSING NORTH WALL 1ST FLOOR |