Permit: T06CM01666


Addresses:

8362 S OTIS DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01666

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/20/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FINISH NAILS IN 2ND FLOOR HIP HANGER
2) NAILS AT GIRDER BEHIND BLKS WHERE THEY CHANGED OUT 2ND FLOOR ROOF AT VERT DUCT CHASE
3) NAIL STUD TO PLATE CLIP EXT. S/EAST CORNER 2ND FLOOR
4) FROM LAST INSPECTION BLOCK ALL OSB TURNED PARALLEL TO TRUSS
5) TRUSS REPAIR FOR NOTCH CLOSER THAN 24" TO HEEL JOINT
6) NO PLAN ON SITE
06/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WRONG NAILS IN ALL HANGERS ROOF (CANNOT USE 8D IN ANY LOAD BEARING HANGER, HANGER NAILS START 10D MINIMUM
2) CONNECT ALL SHEARWALLS TO TRUSS BOTTOM CHORD PER PLAN
3) INSTALL LU 24 HANGERS AT GARAGE SHED ROOF TO 3 1/8" GLU LAM PER PLAN
4) BLOCK AND NAIL FLOOR DECK AT 6" REPAIR
5) BLOCK ALL OSB AT ROOF OSB TURNED WRONG WAY