Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01652
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
12/18/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SCREW AND NAIL 2ND FLOOR |
|
12/15/2006 | FRAMING | Cancelled | IVRS - RI canceled | |
12/07/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* FROM LAST INSP. 1025 EXT. CLIP WIND BRACING INSTALLED FUR IS SECURED. 1. STUDS OVERNOTCHED MORE THAN 1/4" NEW STUD TO DAMAGE STUD 1/4" SPACE MUST BE SHIMMED TIGHT. 2. MISSING TWO A.B'S AT FRONT DEN SHEAR EA. SIDE OF WNDOW. 3. ADD VERT. BLKS. FOR FUR NAILING OF THA FLR. JOIST HANGER ABOVE STAIR AT 1ST FLR 4. BLK & NAIL SCREW FLR WALK ENTIRE 5. MORE SCABS IN 2X4 LOFT CEILING 6. MSTR BATH FAN MISSING DAMPER 7. BLK MECH MSTR CLOSET 8. COMPLETE SHEAR NEXT TO STAIR LTT20 CS STRAP NAIL PBL 2/16 TO SHEAR AND FLR |