Permit: T06CM01641

Parcel: 133390370


Addresses:

9978 E KARST PL


Inspection Status: Cancelled

Inspection History: FRAMING

Permit Number - T06CM01641

Inspection Description - FRAMING

Inspection Status - Cancelled

Date Description Inspector Results Comments
08/01/2006 FRAMING Cancelled
08/01/2006 FRAMING Approved IVRS - Inspection :*
VOID UNDER NE CORNER GARAGE
07/27/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE STAPLES BEHIND HOME RNS
2) FHA STRAP OVER BORES AT HOME RUNS
3) NAIL OFF GIRDER TRUSS BRACKET IN GARAGE
4) SHIM HEADER/TRIMMER CONNECTIONS WHERE NEEDED
5) NEED 2ND KING UNDER TRUSS GIRDER ON EAST BREAKFAST WALL
6) MISSING HIP TRUSS HANGERS IN BREAKFAST
7) FIRE BLOCK CHASE WEST OF BREAKFAST BAY
8) REPAIR FIXTURE HOLE IN ENTRY WAY
9) MISSING CORNER BEAD AT UPPER WEST ENTRY
10) CAULK A/C ELECTRIC
11) STOPPED INSPECTION ENTIRE EAST SIDE OF HOUSE