Permit: T06CM01637


Addresses:

8334 S HUNNIC DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01637

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/07/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/22/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) FROM LAST INSPECTION 1, 2, 4, 5, 6 & 7
2) TRUSS REPAIR NOT PER DETAIL
06/19/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FROM LAST INSPECTION FINISH ITEMS 1, 2, 3, 4 & 5
06/08/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHIM 3 PT BEARING AT GARAGE (LOOK FOR RED PAINT AT PT.)
2) REAR TRUSS AT PORCH ADRE 3 PT BEARING, INSTALLED END FOR END. HAVE TRUSS COMPANY SEND FIX
3) SHIM HEADERS AT BEARING
4) INSTALL ALL RAT RUNS
5) MISSED NAILING ON ROOF MARKED IN BLACK
6) ALL FREIZE BOARDS NOT NAILED
7) TRUSS FIX, NO NOTCHING 24" FROM HEEL