Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01623
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2006 | FRAMING | Approved | IVRS - Inspection :* | |
11/28/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MASTER BATH SHEARWALL REQUIRES NAILS FROM 2 X 12 TO TOP PLATE AT 6" ON CENTER 2) PROVIDE STUD AT MASTER TUB OVERSPAN 3) INSTALL DRYWALL NAILER MASTER BATH |
|
10/18/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK BETWEEN HIGH AND LOW COMBUSTION AIR 2) NO GAS BOND 3) SECURE GROUND MBR CEILING LIGHT 4) ATTIC ACCESS BLOCKED BY PLUMBING 5) MAKE UP ALL GROUND WIRES IN ATTIC BOXES 6) BLOCK DUCT BOOTS 7) RED HEAD ANCHOR BOLTS |