Permit: T06CM01614

Parcel: 140295740

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/25/2006 FRAMING Approved IVRS - Inspection :*
09/20/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1, 4, 5, 6, 8, 9 & 10
2) FIRESTOP OVER ENTRY TRUSSES
09/18/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REINFORCING STRAPS REQUIRED AT ALL OVER NOTCHED TOP PLATE
2) FILL DWV
3) STAPLE WIRES 8" FROM BOX
4) FIRESTOP 2ND FLOOR PENETRATIONS
5) INSUFFICIENT SLOPE ON 3" DRAIN OVER KITCHEN
6) FIREBLOCK STAIR WAY
7) LIGHT IN STAIRWAY TO LOW
8) SEAL VAPOR BARRIER
9) BANG PLATE WIRE-MASTER CLOSET
10) 1" CLEARANCE AROUND B-VENT AND DRAFT STOP AT ATTIC
11) COMPLETE DRYER VENT
12) COMPLETE DUCT TO LAUNDRY
13) STOPPED INSPECTION