Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01614
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/03/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWO NAILS IN BOTTOM PLATE OF WIND BRACES 2) 3RD WIND BRACE REQUIRED ON WEST END OF 1ST FLOOR 3) NAIL HD AT BACK PATIO 4) CLIP INTERIOR BEARING FLOOR TRUSSES TO WALL 5) COMPLETE LATERAL BRACING 6) DBL KING STUDS MISSING EAST AND WEST SIDE OF BLDG 7) WRONG HANGERS AT ROOF TRUSSES 8) NAIL FRIEZE BLOCKS THRU ROOF SHEATHING 9) CHECK ROOF NAILING 10) 18A/SD4 NOT COMPLIED WITH |
|
07/14/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING PAGE SD4-PLAN INCOMPLETE |