Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
| 01/02/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CORRECTIONS HAVE NOT BEEN MADE |
|
| 12/19/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* ELEC. WIRES TOO CLOSE TO WATER HEATER VENT PROVIDE SCREWS IN EXHAUST FAN CONNECTORS. PROVIDE KITCHEN EXHAUST AS PER PLANS SUPERINTENDENT CALL ME PLEASE JIM 909-4712 |
|
| 11/14/2006 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSULATE T-WYE & SIDEWALL REGISTER BOXES. IMPROPER DRYER VENT TERMINATION CRIMPED ENDS WRONG DIRECTION ON DRYER VENT. ELEC. WIRES TOO CLOSE TO WATER HEATER VENT. MAINTAIN MIN. 1" CLEARANCE PROVIDE FRESH AIR FILTER RACK. |