Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2007 | ELECTRIC - INTERMEDIATE | Approved | ||
| 01/02/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK CORRECTIONS, OK INTERIOR ELECTRICAL COVER |
|
| 12/21/2006 | ELECTRIC - INTERMEDIATE | Denied | CORRECTIONS NOT MADE WILL NEED TO PAY REINSPECTION FEE |
|
| 11/15/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. GARAGE AREA SUPPORT ALL ROMEX ABOVE TGI'S 2. CLOSET BEDROOM AT FRONT ENTRY LIFT ALL ROMEX OFF RECESSED LT. 3. SMOKE DETECTOR TO BE 3' AWAY FROM SUPPLY BED RM #1 4. SMOKE DETECTOR TO BE 3' AWAY FROM SUPPLY BED RM #2 5. RECEP. IN LAUNDRY ROOM WEST WALL TO BE ON 20A WASHER CIRCUIT. 6. FRAMER TO REPAIR 2X4 ON RANGE CIRCUIT AT CEILING & WALL ALSO ELEC. TO TAPE INSULATION ON RANGE CIRCUIT WHERE DAMAGED. 7. FRAMER REPAIR 2X4 ABOVE 3 GANG SW AT FAMILY ROOM. |