Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/14/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 07/13/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | PLUMBER HAS PROBLEMS WITH DEPTH AND WITH THE PLAN HE HAS INSTALLED WHAT LOOKS LIKE A WORKABLE SYSTEM NOW WE NEED REDLINES TO MATCH INSTALLATION. |
|
| 07/05/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. PLAN APPROVED IN ERROR. 2. GREASE WASTE NOT INSTALLED PER PLAN - VENT DOWNSTREAM OF TRAP. - FLOW CONTROL AT EACH FIXTURE. 3. USE OF COMBINATION WASTE AND VENT IS NOT WARRANTED NOR IS IT ACCEPTABLE IN THIS APPLICATION. 4. IF CONTRACTOR RECONFIGURES HIS BUILDING DRAIN AND VENTS INTO THE 6" PARTITION HIS PLUMBING WILL WORK ALSO CHANGES REQUIRE REVISION. |