Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/26/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 4, 5 AND 6 FROM PREVIOUS |
|
| 07/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWO NAILS REQUIRED IN BOTTOM PLATE OF WIND BRACES 2) DBL STUD IN 1ST FLOOR WALL UNDER ROOF GIRDER WEST SIDE 3) 20/SD4 AT BACK 4) COMPLETE P2 NAILING AT FRONT PORCH 5) PROVIDE ENGINEERING FOR TRUSS REPAIR 6) CHECK NAILING IN HANGER AT GLU LAM IN GARAGE 7) LUS24 REQUIRED ON GARAGE TRUSSES |
|
| 07/14/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INCOMPLETE PLAN MISSING S-4 |