Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01584
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) ROOF NAILING DOES NOT REQUIRE ADDITIONAL BLOCKS AT EDGE. JUST NAIL SHEATHING INTO 2 X 4 BIRD BOARDS |
|
| 05/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NUMBERS 2, 3 AND 8 NOT DONE |
|
| 05/12/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF BIRD BOARDS PER 2 ON SD3 2) ADD SHEAR UNDER WINDOW BEDROOM AND COMPLETE NAILING SHEARWALL IN BEDROOM 4 3) COMPLETE NAILING SHEAR TOP OF WALL BEDROOM 3 AND SHEAR MASTER BEDROOM 4) ADD STUDS 3 PT BEARING TRUSS A28. REMOVE SHIMS WHERE NONE BEARING 5) ADD STUD AND SHIM A-17 AT MID POINT BEARING 6) WALKED WHOLE ROOF-OK EXCEPT PERIMETER 7) IF POSSIBLE, SUPPLY TRUSS DRAWINGS FOR EACH ELEVATION INSTEAD OF ONE PACKAGE FOR ALL ELEVATIONS 8) NAIL PROTECT PIPES AND CONDUIT AT EXTERIOR OF BOTTOM PLATES |