Permit: T06CM01553

Parcel: 115051140


Addresses:

220 W RILLITO ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/24/2006 FRAMING Approved IVRS - Inspection :*
05/16/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL TRADES
05/09/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 X 10 RAFTERS EXCESSIVELY CUT AND TAPERED
2) H2.5 CLIPS TO BE ATTACHED TO WOOD PLATE UNDER RAFTER NOT ON TO 2 X 4 WALL NORTH END
3) AT EXISTING HOUSE NEED POSITIVE CONNECTION AT BEARING RAFTER TO PLATE; PLATE TO EXISTING RAFTER; EXISTING RAFTER TO EXISTING PLATE; EXISTING PLATE TO MASONRY
4) WILL NEED TO CORRECT ABOVE ITEMS & RECALL 1025 AND 1030
5) DO NOT DRY IN ROOF SHEATHING YET