Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/24/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/16/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES |
|
| 05/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 X 10 RAFTERS EXCESSIVELY CUT AND TAPERED 2) H2.5 CLIPS TO BE ATTACHED TO WOOD PLATE UNDER RAFTER NOT ON TO 2 X 4 WALL NORTH END 3) AT EXISTING HOUSE NEED POSITIVE CONNECTION AT BEARING RAFTER TO PLATE; PLATE TO EXISTING RAFTER; EXISTING RAFTER TO EXISTING PLATE; EXISTING PLATE TO MASONRY 4) WILL NEED TO CORRECT ABOVE ITEMS & RECALL 1025 AND 1030 5) DO NOT DRY IN ROOF SHEATHING YET |