Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM01547
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED NAILING ON ROOF MARKED IN BLACK 2) SHIM 3 PT INTERIOR 3) NEED CANTS/CRICKETS AND VERT OSB AT FRONT BED 4) P.A.'S NOT NAILED 5) MISSING WIND BRACES ON NORTH WALL |