Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01542
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2006 | FRAMING | Approved | IVRS - Inspection :* | |
10/16/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) COMPLY WITH PREVIOUS NUMBERS 5, 6 & 7 2) OK TO INSULATE 3) EXPOSE REPAIRED AREAS |
|
10/12/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |
|
10/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONTINOUS LOAD TRANSFER REQUIRED FROM 2ND FLOOR GIRDERS 2) EXTEND SHEAR TO TOP PLATE 2ND FLOOR 3) 1/4" PER FOOT SLOPE REQUIRED AT WASTE AT GARAGE 4) 10 POUND MINIMUM REQUIRED ON GAS LINE TEST 5) 1" CLEARANCE REQUIRED FROM COMBUSTIBLE TO B-VENTS 6) FIRE BLOCK 2ND FLOOR POP OUT SOUTH SIDE 7) STRAP BEAM TO POST 1ST FLOOR BETWEEN LIVING ROOM AND DINING 8) 2-2 X 8 HEADER REQUIRED OVER KITCHEN WINDOW |
|
07/23/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT COMPLETE ENOUGH TO INSPECT |