Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM01537

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/15/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/11/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. KING STUD UNDER GIRDER IN GARAGE.
2. GARAGE SHEAR WALL NOT NAILED TO PLAN.
3. STRAP ALL PLACES WHERE DOUBLE TOP PLATE HAS BREAKS IN BOTH.
4. NEED RSP 4 N/E CORNER OF GARAGE.
5. OVER NOTCHING DOUBLE TOP PLATE NOT ALLLOWED.
6. STRAP HEADER ON BACK PORCH TO FRAMING.