Permit: T06CM01530

Parcel: 116125700

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
02/14/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
02/12/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1. VENT CONNECTOR UPSIDE DOWN
2. CRIMPED ENDS MUST GO WITH AIRFLOW
3. PROVIDE AN ELBOW & NIPPLE AT BOTTOM OF CONDENSATE DRAIN.
02/02/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT GO TO WITHIN 6" OF THE GROUND
2) INCREASE FURNACE VENT TO 4" AT THE OUTLET ON FURNACE. PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR. DO NOT USE TAPE
3) PROVIDE FUSES IN DISCONNECT
4) LOW VOLTAGE WIRE MUST BE PROTECTED FROM DAMAGE
5) TAPE WHITE WIRE BOTH ENDS WITH BLACK TAPE