Permit: T06CM01530

Parcel: 116125700

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/31/2007 PLUMBING - GAS PRESSURE TEST Approved
12/28/2006 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) SHALL PROVIDE APPROVED COUPLINGS FOR PIPING
2) SHALL PRIME & THEN 10 MIL TAPE ALL TOOL MARKS AND FITTING ON UNDERGROUND PIPING AND HAVE PIPING IN DITCH ON FIRM BONDING MINIMUM 12" OF COVER
3) SHALL PROVIDE CORRECT COMBUSTION AIR FOR FURNACE
4) SHALL PROVIDE SEDIMENT TRAPS AT WATER HEATER
5) SHALL PROVIDE APPROVED GAS VALVE AND RIGID PIPE NIPPLE THRU WATER HEATER WEATHER PROOF ENCLOSURE
6) SHALL PROVIDE BONDING OF BLDG GAS PIPING
7) PROVIDE PERMIT AND INSPECTION FOR NEW AC/FURNACE UNIT TO OBTAIN GAS CLEARANCE CARD