Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 04/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BROKEN CRIPPLE 2ND FLOOR WINDOW HEADER 2) FRIEZE BOARDS NOT NAILED AT ROOF DECK 3) MISSED TWO FOUR FT NAILING LINES ON ROOF MARKED IN BLACK 4) SHEAR WALLS 7-9 GET A35'S OR A35F AT 24" ON CENTER OR IF SCHEDULE SAYS SHEAR TO DRAG TRUSS BOTTOM CHORD DIFFERENCE 5) SHEWALLS 1-5 GET 16D COMMON NAILS 12" ON CENTER SHEAR TO DRAG TRUSS 6) FINISH FRONT PORCH 7) 4 X 6 HEADER INSTALLED FRONT BEDROOM 4 X 8 REQUIRED 8) 48" LONG STRAPS, SEE PLAN 1ST & 2ND FLOOR |