Permit: T06CM01527

Parcel: 140551060

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/27/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/24/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BROKEN CRIPPLE 2ND FLOOR WINDOW HEADER
2) FRIEZE BOARDS NOT NAILED AT ROOF DECK
3) MISSED TWO FOUR FT NAILING LINES ON ROOF MARKED IN BLACK
4) SHEAR WALLS 7-9 GET A35'S OR A35F AT 24" ON CENTER OR IF SCHEDULE SAYS SHEAR TO DRAG TRUSS BOTTOM CHORD DIFFERENCE
5) SHEWALLS 1-5 GET 16D COMMON NAILS 12" ON CENTER SHEAR TO DRAG TRUSS
6) FINISH FRONT PORCH
7) 4 X 6 HEADER INSTALLED FRONT BEDROOM 4 X 8 REQUIRED
8) 48" LONG STRAPS, SEE PLAN 1ST & 2ND FLOOR