Permit: T06CM01502

Parcel: 140551050

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/17/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/16/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLETE SHEARWALL NAILING AT REAR OF HOUSE
2) TWO NAILS REQUIRED AT TOP AND BOTTOM PLATE OF WIND BRACES
3) 15/DT1 NOT COMPLIED WITH BLOCK AND NAIL UNDER OVER FRAME, CLIP TRUSSES AND STUDS BEARING WALLS AND BEARING WALL REQUIRES DBL TOP PLATE
4) 10/DT1 NOT COMPLIED WITH BLOCKS MUST BE TIGHT TO TOP PLATE
5) 3 KING STUDS REQUIRED AT GARGE HDR
6) A35 REQUIRED 16" ON CENTER AT REAR GABLE 6/DT1
7) STOPPED INSPECTION