Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T06CM01488
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2007 | ROOF NAILING | Approved | IVRS - Inspection :* | |
02/14/2007 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE APPROVED DETAILS FOR ALL BEAM AND GIRDER CONNECTION TO CMU WALLS 2) APPROVED DETAIL REQUIRED FOR AS BUILT BEAM TO POST CONNECTION 3) ADD A-35'S TO ALL TOP CORD OF JACK TRUSSES 4) 2" CLEARANCE REQUIRED AROUND FIREPLACE TO COMBUSTIBLE 5) NAIL SHEATHING WHERE INDICATED AND AS PER APPROVED DRAWINGS |