Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM01480

Parcel: 119421480

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/05/2006 FRAMING Approved IVRS - Inspection :*
06/29/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANTI-SIPHON ON HOSE BIB
2) STAPLE LATHE OVER PATIO ON GABLE
3) STAPLE LATH AT GARAGE DOOR
4) FHA STRAP AT TOP PLATE BY GAS LINE
5) 6 NAILS REQUIRED IN EACH FHA STRAP AT A/C COPPER
6) COMBUSTION AIR VENTS ?
7) TIGHTEN ANCHOR BOLTS
8) FILL DWV
9) STOPPED INSPECTION