Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/01/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS HANGER MISSING IN GARAGE 2) HANGERS NOT NAILED OFF 3) STRAP IN GARAGE NOT NAILED 4) BACK PORCH BEAM MUST BE STRAPED TO PLATE NOT STUD 5) TWO NAILS REQUIRED IN BOTTOM PLATE AT WIND BRACES 6) PROTECT PLUMBING AT BOTTOM PLATES 7) TWO CLIPS REQUIRED AT GIRDERS 8) PROVIDE TRUSS SPECS 9) AB REQUIRED AT INTERIOR GARAGE AT GIRDER 10) CLIP STUDS AT INTERIOR BEARING 11) STOPPED INSPECTION-NEXT FAILURE WILL RESULT IN REFEE |