Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/08/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MAS STRAPS NOT NAILED. 2. 2" STRIPS ON SHEAR NOT ACCEPTABLE. 3. SHEAR NOT REACHING DOUBLE TOP PLATE. 4. GIRDER IN GARAGE MISSING KING STUD. 5. ATTACH GABLE END. 6. ATTACH HEADERS WITH STRAPS. 7. STRAP ALL LOCATION ON DOUBLE TOP PLATE AT POINTS WHERE THERE IS A BREAK ON BOTH PLATES. 8. STRAP DOUBLE TO HEADER ON SHOWER WINDOW. 9. MISSING CONNECTION FROM WALL TO TOP PLATE WEST SIDE. 10. BANG PLATES THROUGHOUT. STOPPED INSPECTION. |