Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM01462

Parcel: 140261240

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T06CM01462

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
04/26/2006 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/25/2006 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHAIRS UNDER CABLE SOUTH SIDE OF GARAGE STEMWALL
2) HAIR PINS TOUCHING DIRT
3) 1/2 DIAMETER REBAR AT H.D.'S