Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T06CM01461

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
07/27/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CANNOT FIND WEST SIDE PROPERTY PIN
2) VERIFY FRONT SETBACK
3) PLAN CALLS FOR U.P.C. PLUMBING, IRC REQUIRES AN APPEAL FROM CITY, IRC INSTALLED
4) NO ISOMETRIC ON PKLAN. PLAN IS U.P.C.
5) HCS COVERED
6) BACK WATER VALVE INSTALLED, COMBOS, TURNED WRONG WAY AT B.W. VALVE
7) 2 STORY REQUIRES, TWO TRUNK LINES
8) PROJECTIONS INTO 3' FIRE RATING SIDE YARD WEST
9) PLEASE STAPLE PLANS TOGETHER
10) WILL NEED APPROVED IRC PLUMBING PLAN WITH ISOMETRIC
07/06/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS OR PERMIT ON SITE