Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/01/2007 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 07/27/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CANNOT FIND WEST SIDE PROPERTY PIN 2) VERIFY FRONT SETBACK 3) PLAN CALLS FOR U.P.C. PLUMBING, IRC REQUIRES AN APPEAL FROM CITY, IRC INSTALLED 4) NO ISOMETRIC ON PKLAN. PLAN IS U.P.C. 5) HCS COVERED 6) BACK WATER VALVE INSTALLED, COMBOS, TURNED WRONG WAY AT B.W. VALVE 7) 2 STORY REQUIRES, TWO TRUNK LINES 8) PROJECTIONS INTO 3' FIRE RATING SIDE YARD WEST 9) PLEASE STAPLE PLANS TOGETHER 10) WILL NEED APPROVED IRC PLUMBING PLAN WITH ISOMETRIC |
|
| 07/06/2007 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS OR PERMIT ON SITE |