Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM01459
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2006 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
05/04/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PLUMBING OK TEST AND WRAPPED. 2. PER FOUNDATION PLAN 12"X16' MONO FTG AT BATHROOM FOOTER W/2 #U 3. REMOVE LOOSE FILL FROM FOOTINGS AND SLAB AT REAR BATH. |
|
05/03/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CANNOT HAVE LARGER THAN 3" SQUARE CONCRETE HOLDING UP REBAR 2) FOOTINGS TO BEAR MINIMUM 12" BELOW NATURAL GRAB 3) WRAP ALL PLUMBING IN CONTACT WITH CONCRETE 4) REBAR TO HAVE 3" CLEARANCE TO DIRT AND EXISTING CONCRETE FORMS 5) REMOVE ALL LOOSE DIRT IN FOOTINGS 6) STOPPED INSPECTION |
|
05/01/2006 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* 1) PLUMBING LAYOUT OK 2) NEED 10' HEAD TEST & WRAPS |
|
04/30/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SANTEE NOT PERMITTED HORIZONTAL 2) TOILET NOT VENTED PROPERLY VENT SHALL BE IN FRONT OF FIXTURE WITH FITTING AT 45 DEGREE 3) EXPOSE CONNECTION TO EXISTING SEWER |
|
04/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
04/25/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER MONO FTG DETAIL 2 #4 CONT, AT FOOTER 16" 2) WRAP ALL PLUMBING 3) NO INSPECTION CARD ON SITE |
|
04/19/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSING PER PLAN 2" WITH 1 1/2" VTR @ NEW LAUNDRY 2. PROVIDE 10' HEAD PRESSURE TEST 3. NEGATIVE PITCH ALL PLUMBING 4. PER PLAN BATH FOOTER 2 #4 REBAR AT FOOTER 5. MISSING FOOTER CARPORT SOUTHEND 6. INSTALL REBAR 2 #4 EACH WAY CARPORT FOOTERS. |
|
04/18/2006 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* |