Permit: T06CM01450

Parcel: 119421550

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/22/2006 FRAMING Approved IVRS - Inspection :*
06/20/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXTEND UFER
2) RAISE SMOKIE
3) APPROVED TO INSULATE
4) PROVIDE INSPECTION HOLE
06/16/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. COMPLETE STUCCO MESH
2. FHA STRAP @ TOP PLATE
GAS SERVICE
3. EXTEND UFER
4. PEX TOO CLOSE TO B-VENT
5. FHA STRAP @ DRYER VENT
6. SEAL VAPOR BARRIER
7. ANCHOR BOLTS MISSING
M. CLOSET
8. SMOKE IN GREAT ROOM TOO LOW
9. PROVIDE ACCESS TO ATTIC.
M. CLOSET
10. ROOF VENTING METHOD?