Permit: T06CM01446

Parcel: 141095490


Addresses:

6378 E STAR MICA ST


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T06CM01446

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/06/2007 BUILDING - FINAL Approved IVRS - Inspection :*
04/04/2007 BUILDING - FINAL Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
1. NO GAS VENT WEATHERCAPS REPEAT (REFEE)
2. HOSE BIBS REQUIRE NON-REMOVABLE ANTI-SIPHON VALVE REPORT (REFEE)
3. NO LADDER ACCESS TO INSPECT FURNACE
03/30/2007 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER KEN
03/29/2007 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
03/26/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS NOT FIXED FROM 3/19/07
03/19/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO B-VENT CAPS
2) NO ADDRESS
3) NO POST TENSION TAG
4) HOSE BIBS REQUIRE ANTI-SIPHON VALVE
5) HAND RAIL AT WINDER MUST EXTEND OVER TOP RISER
6) SECURE GAS LINE HINGE JOINT BY FURNACE
7) SEAL W/H LID