Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM01446
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
10/19/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) W/H B-VENT MUST RISE MINIMUM 30 DEGREES 2) B-VENT MUST HAVE 1" CLEARANCE TO COMBUSTIBLE ABS 3) DWV LEAK AT CLOSET ?-DO NOT EXTERNAL GLUE 4) HALL MUST BE 36" WIDE FINISHED 5) SEAL VAPOR BARRIER ON STUCCO 6) STAIR OS20 STRAP MUST BE ON SHEARWALL |